1 built-in thermistor temperature with measurement range -40 to +70°C. 'D' Indicates LCD display.
GC06
Built-in digital RH and temperature sensor.
'C' indicates standard case without display.
'D' indicates display.
'W' indicates white finish.
The transmitter retains all of the GenII transmitter hallmarks whilst adding in logging capabilities, with storage for approximately 52,000 readings.
The GDLM10 can be used for monitoring objects in transit, for example museum exhibits. The unit is removed from its normal location, transported with the object, and upon reaching its destination, the readings can be downloaded and optionally added into a database, for continuous monitoring.
The GDLM10 can also be used as a standalone environmental monitoring solution, with data being downloaded from the unit for analysis.
We offer a range of software compatible with the unit, depending on the user requirements.
'D' indicates display.
'W' indicates white finish.
GD10
Built-in digital RH and temperature sensor & external thermistor input. With display.*
GD11
* (Tini QG connector not included, order separately. Specify connector Code 4 when ordering probe)
This kit enables fitment of the transmitter's built-in wall bracket to difficult or uneven surfaces. The kit provides additional docking security.
The following products are supported:
WBG
Model(s) | Sensors | Range | Resolution | Accuracy |
---|---|---|---|---|
GC06/GD06 | built-in thermistor | -40 to +70°C | 0.1°C | ±0.2°C (-15 to +40°C) |
0.2°C | ±0.4°C (-29 to +65°C) | |||
0.3°C | ±0.6°C (-36 to +70°C) | |||
0.4°C | ±0.8°C (-40 to -36°C) | |||
GC10/GD10 | built-in temperature | -30 to 65°C | 0.1°C | ±0.4°C (+5 to +40°C) |
±1.0°C (-20 to +65°C) | ||||
±1.5°C (-30 to -20°C) | ||||
built-in RH | 0-100% | 0.1% | ±2% (10 to 90%RH) | |
±4% (0 to 100%RH) | ||||
GD11 | built-in temperature and RH | As GC10 | ||
external thermistor temperature | -15 to 40°C | 0.1°C | ±0.3°C | |
-30 to 65°C | 0.2°C | ±0.5°C |
RF specification: | EN300-220 | |
RF power: | 10mW | |
Environment specification | ||
Compliant to EN300-220: | -10 to +55°C | |
Actual: | -30 to +65°C | |
Humidity: | 100% non condensing | |
Environmental rating: | IP40 | |
Dimensions (footprint): | 78 x 41mm | |
Transmission interval range: | 1 sec to 4 hours | |
Indicator (red LED): | transmit active/on/off | |
Control switch (concealed): | test mode / hibernate | |
Antenna socket: | SMA |
Gen II Quick Start Instructions
GenII transmitters for humidity & temperature
GDLM10 simultaneous transmitter and logger for humidity & temperature