Transmitters with inputs for pulse and state

Connectors are included.

GC60 2 x state inputs (e.g. door open/close) GS-31
GC60Y 2 x count inputs to monitor the opening and closing of one or two contacts (e.g. a door or window magnet activated contact).
4 x calculated channels providing additional data about the relationship between the states of the two doors/windows.
GS34 or GS24 4 x state inputs (e.g. door open/close)
GS38 8 x state inputs (e.g. door open/close)
GC62 / GC62A 2 x pulse inputs (voltage-free or digital: 250Hz max).
'A' denotes inverted input.
GC62B 2 x pulse inputs, input A for optisense LED meter flash sensor and input B as GC62. Optisense sensor must be ordered seperately.
new
GC62EX
2 x pulse inputs (voltage free or digital: 250Hz max). The GC62EX is designed to meet the requirements of IGEM / GM / 7A communications 1731 for connection to a domestic gas meter.
new
GD67 / GD67A
7 x pulse inputs (voltage-free or digital: 15Hz max) with external power connection. With display.
'A' denotes inverted input.
new
GD68 / GD68A
8 x pulse inputs (voltage-free or digital: 15Hz max). With display.
'A' denotes inverted input.

 

 

 

 

Sensors

PRO1TE Rayleigh energy monitor PRO1TE with pulse output for use with GC62, GD67 and GD68.

Range 0-45A (1 pulse per 0.5wh).
PRO1
PRO75D Rayleigh energy monitor PRO75D-P with pulse output for use with GC62, GD67 and GD68.

Range 0-100A (1600 pulses per kWh).
PRO75D
A100C Elster A100C energy monitor with pulse output for use with GC62, GD67 and GD68.

Range 10-100A (1 pulse per 10Wh).
AC100C
Flownetix 315 Water flow FLownetix 315

Accessories

Common Specification

RF specification: EN300-220
RF power: 10mW
Environment specification  
  Compliant to EN300-220: -10 to +55°C
  Actual: -30 to +65°C
  Humidity: 100% non condensing
Environmental rating: IP40
Dimensions (footprint): 78 x 41mm
Battery endurance: up to 5 years (interval set to 5 minutes) (less for GL-70 and GS40 series)
Transmission interval range: 1 sec to 4 hours
Indicator (red LED): transmit active/on/off
Control switch (concealed): test mode / hibernate
Antenna socket: SMA

Transmitter Specification

Model(s) Sensors
GC60 2 x state indications
GC60F 2 x state indications for flood sensors only
GC60Y 2 x physical inputs indicating the number of open and close events of the door contact.
2 x one second counters to provide the accumulative total of how long the door contacts on the physical inputs were open.
1 x count (accumulated) of the number of times both doors are open together.
1 x one second counter for previous channel showing accumulative total of how long both doors were open together (shown in seconds).
GC62EX 2 x pulse inputs for connection to domestic gas meter
GC62/GC62a 2 x pulse inputs (/a inverted input)
GD67 7 x pulse inputs
GD68/GD68a 8 x pulse inputs (/a inverted input)